IFM O1D100 O1DLF3KG/IO-LINK SENSOR MALAYSIA
Photoelectric distance sensor
O1D100
O1DLF3KG/IO-LINK
-
Reliable optical distance measurement with high ranges up to 10 m
-
Two switching outputs, one of them programmable as analogue output
-
Scalable measuring range and window function
-
Use in applications with background suppression
-
Excellent price/performance ratio
Product characteristics
|
Laser protection class |
2 |
|
Housing |
rectangular |
Electrical data
|
Operating voltage[V] |
18...30 DC; (''supply class 2'' to cULus) |
|
Current consumption[mA] |
< 150 |
|
Protection class |
III |
|
Reverse polarity protection |
yes |
|
Typ. lifetime[h] |
50000 |
Inputs / outputs
|
Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
Outputs
|
Total number of outputs |
2 |
|
Electrical design |
PNP |
|
Number of digital outputs |
2 |
|
Output function |
normally open / normally closed; (parameterisable) |
|
Max. current load per output[mA] |
200 |
|
Number of analogue outputs |
1 |
|
Analogue current output[mA] |
4...20; (IEC 61131-2) |
|
Max. load[Ω] |
250 |
|
Analogue voltage output[V] |
0...10; (IEC 61131-2) |
|
Min. load resistance[Ω] |
5000 |
|
Short-circuit protection |
yes |
|
Type of short-circuit protection |
pulsed |
|
Overload protection |
yes |
Detection zone
|
Max. light spot width[mm] |
15 |
|
Max. light spot height[mm] |
15 |
|
Light spot dimensions refer to |
10 m |
|
Background suppression[m] |
0...19 |
Measuring/setting range
|
Measuring range[m] |
0.2...10; (white paper 200 x 200 mm 90% remission) |
|
Sampling rate[Hz] |
1...50 |
Interfaces
|
Communication interface |
IO-Link |
|
Transmission type |
COM2 (38,4 kBaud) |
|
IO-Link revision |
1.1 |
|
SDCI standard |
IEC 61131-9 |
|
Profiles |
Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis |
|
SIO mode |
yes |
|
Required master port type |
A |
|
Process data analogue |
2 |
|
Process data binary |
3 |
|
Min. process cycle time[ms] |
6 |
|
Supported DeviceIDs |
|
Type of operation |
DeviceID |
|
default |
806 |
|
Operating conditions
|
Ambient temperature[°C] |
-10...60 |
|
Protection |
IP 67 |
Tests / approvals
|
EMC |
|
|
Laser protection class |
2 |
|
Notes on laser protection |
|
Caution: |
laser light |
|
Power: |
<= 4 mW |
|
Wave length: |
650 nm |
|
pulse: |
1,3 ns |
|
Do not stare into beam. |
|
|
Avoid exposure to the laser light. |
|
|
laser class: |
2 |
|
|
EN / IEC60825-1:2007 |
|
|
EN / IEC60825-1:2014 |
|
|
Complies with 21 CFR 1040.10 except for conformance with IEC 60825-1 Ed. 3, as described in Laser Notice No. 56, dated May 8, 2019. |
|
|
MTTF[years] |
182 |
Mechanical data
|
Weight[g] |
243.5 |
|
Housing |
rectangular |
|
Dimensions[mm] |
59 x 42 x 52 |
|
Materials |
housing: diecast zinc; front pane: glass; LED window: PC |
|
Lens alignment |
side lens |
Displays / operating elements
|
Display |
|
switching status |
2 x LED, yellow |
|
operation |
LED, green |
|
distance value, programming |
alphanumeric display, 4-digit |
|
Remarks
|
Remarks |
|
For more information about the measuring range / application please refer to the operating instructions. |
|
|
Pack quantity |
1 pcs. |
Electrical connection
|
Connection |
Connector: 1 x M12; coding: A |
Other data
|
Parameter |
Setting range |
Factory setting |
|
Uni |
mm, m, inch |
mm |
|
OU1 |
Hno, Hnc, Fno, Fnc |
Hno |
|
SP1 [mm] |
200...9999 |
1000 |
|
nSP1 [mm] |
200...9999 |
800 |
|
FSP1 [mm] |
200...9999 |
1200 |
|
OU2 |
Hno, Hnc, Fno, Fnc, I, U |
I |
|
SP2 [mm] |
200...9999 |
2000 |
|
nSP2 [mm] |
200...9999 |
1800 |
|
FSP2 [mm] |
200...9999 |
2200 |
|
ASP [mm] |
0...9999 |
0 |
|
AEP [mm] |
0...9999 |
9999 |
|
rATE [Hz] |
1...50 |
50 |
|
dS1 [s] |
0...0.1...5 |
0 |
|
dr1 [s] |
0...0.1...5 |
0 |
|
dS2 [s] |
0...0.1...5 |
0 |
|
dr2 [s] |
0...0.1...5 |
0 |
|
dFo [s] |
0...0.1...5 |
0 |
|
dIS |
d1...3 ; rd1...3; OFF |
d3 |
|
read/write distance (mm) |
repeatability of the measured values |
|
accuracy |
|
|
|
white (90 % remission) |
grey (18 % remission) |
white (90 % remission) |
grey (18 % remission) |
|
200...1000 mm |
± 5.0 mm |
±7.5 mm |
± 15.0 mm |
± 18.0 mm |
|
1000...2000 mm |
± 5.5 mm |
±10.0 mm |
± 15.0 mm |
± 20.0 mm |
|
2000...4000 mm |
± 17.5 mm |
±22.5 mm |
± 25.0 mm |
± 32.0 mm |
|
4000...6000 mm |
± 27.5 mm |
±40.0 mm |
± 35.0 mm |
± 50.0 mm |
|
6000...10000 mm |
± 60.0 mm |
|
± 70.0mm |
|
|
read/write distance (mm) |
repeatability of the measured values |
|
accuracy |
|
|
|
white (90 % remission) |
grey (18 % remission) |
white (90 % remission) |
grey (18 % remission) |
|
200...1000 mm |
± 16.5 mm |
±16.5 mm |
± 26.5 mm |
± 26.5 mm |
|
1000...2000 mm |
± 16.5 mm |
±16.5 mm |
± 26.5 mm |
± 26.5 mm |
|
2000...4000 mm |
± 30.0 mm |
±37.0 mm |
± 40.0 mm |
± 47.0 mm |
|
4000...6000 mm |
± 37.0 mm |
±57.0 mm |
± 47.0 mm |
± 67.0 mm |
|
6000...10000 mm |
± 75.0 mm |
— |
± 85.0mm |
— |
|
read/write distance (mm) |
repeatability of the measured values |
|
accuracy |
|
|
|
white (90 % remission) |
grey (18 % remission) |
white (90 % remission) |
grey (18 % remission) |
|
200...1000 mm |
± 4.0 mm |
±4.5 mm |
± 14.0 mm |
± 15.0 mm |
|
1000...2000 mm |
± 4.5 mm |
±6.0 mm |
± 14.5 mm |
± 16.0 mm |
|
2000...4000 mm |
± 13.5 mm |
±14.5 mm |
± 23.5 mm |
± 24.0 mm |
|
4000...6000 mm |
± 19.0 mm |
±21.0 mm |
± 29.0 mm |
± 31.0 mm |
|
6000...10000 mm |
± 37.0 mm |
– |
± 47.0mm |
– |
|
read/write distance (mm) |
repeatability of the measured values |
|
accuracy |
|
|
|
white (90 % remission) |
grey (18 % remission) |
white (90 % remission) |
grey (18 % remission) |
|
200...1000 mm |
± 10.0 mm |
± 10.0 mm |
± 20.0 mm |
± 20.0 mm |
|
1000...2000 mm |
± 10.0 mm |
± 10.0 mm |
± 20.0 mm |
± 20.0 mm |
|
2000...4000 mm |
± 17.0 mm |
± 18.0 mm |
± 27.0 mm |
± 28.0 mm |
|
4000...6000 mm |
± 22.0 mm |
± 25.0 mm |
± 32.0 mm |
± 35.0 mm |
|
6000...10000 mm |
± 37.0 mm |
– |
± 47.0mm |
– |