Visit
Official Website

IFM O1D100 O1DLF3KG/IO-LINK SENSOR MALAYSIA

Previous 2 / 4 Next


Photoelectric distance sensor

O1D100

 O1DLF3KG/IO-LINK


 
  • Reliable optical distance measurement with high ranges up to 10 m
  • Two switching outputs, one of them programmable as analogue output
  • Scalable measuring range and window function
  • Use in applications with background suppression
  • Excellent price/performance ratio
  • ce
  • ukca
  • cul
  • iolink

Product characteristics

Laser protection class 2
Housing rectangular

Electrical data

Operating voltage[V] 18...30 DC; (''supply class 2'' to cULus)
Current consumption[mA] < 150
Protection class III
Reverse polarity protection yes
Typ. lifetime[h] 50000

Inputs / outputs

Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1

Outputs

Total number of outputs 2
Electrical design PNP
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. current load per output[mA] 200
Number of analogue outputs 1
Analogue current output[mA] 4...20; (IEC 61131-2)
Max. load[Ω] 250
Analogue voltage output[V] 0...10; (IEC 61131-2)
Min. load resistance[Ω] 5000
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes

Detection zone

Max. light spot width[mm] 15
Max. light spot height[mm] 15
Light spot dimensions refer to 10 m
Background suppression[m] 0...19

Measuring/setting range

Measuring range[m] 0.2...10; (white paper 200 x 200 mm 90% remission)
Sampling rate[Hz] 1...50

Interfaces

Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis
SIO mode yes
Required master port type A
Process data analogue 2
Process data binary 3
Min. process cycle time[ms] 6
Supported DeviceIDs
Type of operation DeviceID
default 806

Operating conditions

Ambient temperature[°C] -10...60
Protection IP 67

Tests / approvals

EMC
EN 60947-5-2  
Laser protection class 2
Notes on laser protection
Caution: laser light
Power: <= 4 mW
Wave length: 650 nm
pulse: 1,3 ns
Do not stare into beam.  
Avoid exposure to the laser light.  
laser class: 2
  EN / IEC60825-1:2007
  EN / IEC60825-1:2014
  Complies with 21 CFR 1040.10 except for conformance with IEC 60825-1 Ed. 3, as described in Laser Notice No. 56, dated May 8, 2019.
MTTF[years] 182

Mechanical data

Weight[g] 243.5
Housing rectangular
Dimensions[mm] 59 x 42 x 52
Materials housing: diecast zinc; front pane: glass; LED window: PC
Lens alignment side lens

Displays / operating elements

Display
switching status 2 x LED, yellow
operation LED, green
distance value, programming alphanumeric display, 4-digit

Accessories

Accessories (optional)
Protective cover, E21133

Remarks

Remarks
For more information about the measuring range / application please refer to the operating instructions.
Pack quantity 1 pcs.

Electrical connection

Connection Connector: 1 x M12; coding: A

Other data

Parameter Setting range Factory setting
Uni mm, m, inch mm
OU1 Hno, Hnc, Fno, Fnc Hno
SP1 [mm] 200...9999 1000
nSP1 [mm] 200...9999 800
FSP1 [mm] 200...9999 1200
OU2 Hno, Hnc, Fno, Fnc, I, U I
SP2 [mm] 200...9999 2000
nSP2 [mm] 200...9999 1800
FSP2 [mm] 200...9999 2200
ASP [mm] 0...9999 0
AEP [mm] 0...9999 9999
rATE [Hz] 1...50 50
dS1 [s] 0...0.1...5 0
dr1 [s] 0...0.1...5 0
dS2 [s] 0...0.1...5 0
dr2 [s] 0...0.1...5 0
dFo [s] 0...0.1...5 0
dIS d1...3 ; rd1...3; OFF d3
repeatability/accuracy
read/write distance (mm) repeatability of the measured values   accuracy  
  white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission)
200...1000 mm ± 5.0 mm ±7.5 mm ± 15.0 mm ± 18.0 mm
1000...2000 mm ± 5.5 mm ±10.0 mm ± 15.0 mm ± 20.0 mm
2000...4000 mm ± 17.5 mm ±22.5 mm ± 25.0 mm ± 32.0 mm
4000...6000 mm ± 27.5 mm ±40.0 mm ± 35.0 mm ± 50.0 mm
6000...10000 mm ± 60.0 mm   ± 70.0mm  
repeatability/accuracy
read/write distance (mm) repeatability of the measured values   accuracy  
  white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission)
200...1000 mm ± 16.5 mm ±16.5 mm ± 26.5 mm ± 26.5 mm
1000...2000 mm ± 16.5 mm ±16.5 mm ± 26.5 mm ± 26.5 mm
2000...4000 mm ± 30.0 mm ±37.0 mm ± 40.0 mm ± 47.0 mm
4000...6000 mm ± 37.0 mm ±57.0 mm ± 47.0 mm ± 67.0 mm
6000...10000 mm ± 75.0 mm ± 85.0mm
repeatability/accuracy
read/write distance (mm) repeatability of the measured values   accuracy  
  white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission)
200...1000 mm ± 4.0 mm ±4.5 mm ± 14.0 mm ± 15.0 mm
1000...2000 mm ± 4.5 mm ±6.0 mm ± 14.5 mm ± 16.0 mm
2000...4000 mm ± 13.5 mm ±14.5 mm ± 23.5 mm ± 24.0 mm
4000...6000 mm ± 19.0 mm ±21.0 mm ± 29.0 mm ± 31.0 mm
6000...10000 mm ± 37.0 mm ± 47.0mm
repeatability/accuracy
read/write distance (mm) repeatability of the measured values   accuracy  
  white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission)
200...1000 mm ± 10.0 mm ± 10.0 mm ± 20.0 mm ± 20.0 mm
1000...2000 mm ± 10.0 mm ± 10.0 mm ± 20.0 mm ± 20.0 mm
2000...4000 mm ± 17.0 mm ± 18.0 mm ± 27.0 mm ± 28.0 mm
4000...6000 mm ± 22.0 mm ± 25.0 mm ± 32.0 mm ± 35.0 mm
6000...10000 mm ± 37.0 mm ± 47.0mm