SJT SUCCESS INDUSTRIAL AUTOMATION SDN. BHD. added new photo in SIEMENS - SIMOTICS MOTOR
Nov 25, 2025 at 02:06 pm —
Siemens 1FK2208-5AC11-0MA0 Simotics S Synchronous Motor Malaysia

Siemens 1FK2208-5AC11-0MA0 Simotics S Synchronous Motor Malaysia

Specifications Product related Article number 1FK2208-5AC11-0MA0 MFN 1FK22085AC110MA0 Life cycle status Active Product Product Family 1FK2 servomotors for SINAMICS S210 EAN 4025515680352 UPC 195125461055 Commodity Code 85015220 Pricing related Customer Price – List Price – Price Group A97 Surcharge for raw material Metal Factor ------71 Delivery related Export Control Regulations AL : N / ECCN : N_CNDU Standard delivery time 15 Day/Days Packaging dimensions (L x W x H) 17.795 x 9.843 x 10.512 in Net weight 42.549 lb Quantity Unit 1 Piece Packaging Quantity 1 Dangerous goods No Environment related WEEE (2012/19/EU) Take-Back Obligations Yes Compliance with the substance restrictions according to RoHS directive Since: 07/01/2006 REACH Art. 33 Duty to inform according to the current list of candidates Reach Information SCIP Number not available Sustainability Siemens specific Product Group 4R42 Catalog ID D32 Group Code R220 Country of origin Germany Returnable Status No read more
SJT SUCCESS INDUSTRIAL AUTOMATION SDN. BHD. added new photo
Nov 25, 2025 at 01:43 pm —
SJT SUCCESS INDUSTRIAL AUTOMATION SDN. BHD. added 2 new photos in SIEMENS - SIMATIC S7
Nov 25, 2025 at 01:34 pm —
Siemens 6ES7332-1HH01-0AA0 SIMATIC S7-300 Malaysia
Siemens 6EP1333-4BA00 SIMATIC PM 1507 Malaysia
SJT SUCCESS INDUSTRIAL AUTOMATION SDN. BHD. added new photo in OMRON - OMRON RELAY
Nov 25, 2025 at 12:57 pm —
Omron G9SE-401 Safety Relay Malaysia

Omron G9SE-401 Safety Relay Malaysia

Power Input   Model G9SE-401 Rated supply voltage 24 VDC Operating voltage range -15% to 10% of rated supply voltage Rated power consumption *1 4 W max.   Outputs   Model G9SE-401 Safety output OFF-delayed Safety output Contact output 250 VAC 5 A 30 VDC 5 A (resistive load) Auxiliary output PNP transistor output Load current: 100 mA DC max.   Characteristics   Model G9SE-401 Operating time (OFF to ON state) *2 100 ms Max. *3 Response time (ON to OFF state) *4 15 ms Max. Accuracy of OFF-delay time - Inputs Input current 5 mA Min. ON voltage 11 VDC Min. OFF voltage 5 VDC Max. OFF current 1 mA Max. Maximum cable length 100 m Max. Reset input time 250 ms Min. Contact outputs Contact resistance *5 100 mΩ Mechanical durability 5,000,000 operations Min. Electrical durability 50,000 operations Min. Switching specification Inductive load (IEC/EN60947-5-1) AC15: 240 VAC 2 A DC13: 24 VDC 1.5 A Minimum applicable load 24 VDC 4 mA Conditional short-circuit current (IEC/EN60947-5-1) 100 A *6 Pollution degree 2 Over voltage category (IEC/EN60664-1) Safety output: Class III, the others: Class II Insulation specification Isolation voltage (Ui) 250 VAC Impulse withstand voltage (IEC/ EN60947-5-1) Between input and output 6 kV Between different poles of output 6 kV (between 13-14/23-24 and 33-34/43-44 (37-38/47-48)) 4 kV (between 13-14 and 23-24, between 33-34 (37-38) and 43-44 (47-48)) Dielectric strength Between input and output 2,200 VDC Between different poles of output 1,500 VAC Insulation resistance 100 MΩ Vibration resistance *7 Frequency: 10 to 55 to 10 Hz Amplitude: 0.35 mm half amplitude (0.7 mm double amplitude) Mechanical shock re- sistance *7 Destruction 300 m/s2 Malfunction 100 m/s2 Surrounding Air Temperature -10 to 55°C (No freezing or condensation) Ambient humidity 25% to 85%RH Degree of protection IP20 Weight approx. 180 g read more
SJT SUCCESS INDUSTRIAL AUTOMATION SDN. BHD. added new photo in OMRON - OMRON HMI
Nov 14, 2025 at 04:29 pm —
Omron NS5-MQ00-V2 Malaysia

Omron NS5-MQ00-V2 Malaysia

Description: NS5MQ00V2 OPERATOR INTERFACE 5.7 INCH STN SCREEN MONOCHROME 320 X 240 24 VDC 15 W WITHOUT ETHERNET IVORY read more
SJT SUCCESS INDUSTRIAL AUTOMATION SDN. BHD. added new photo in SMC
Nov 14, 2025 at 04:05 pm —
SMC ASV310F-01-08S Speed Exhaust Controller Malaysia

SMC ASV310F-01-08S Speed Exhaust Controller Malaysia

Series ASV, speed exhaust controller provides an effective area that is two times larger than that of a speed controller. A silencer, one-touch fitting and flame resistant resin body is supplied as standard on the ASV. All brass parts are electroless nickel-plated. SMC Part Description:tab 4 SPD EXHAUST CONTROLLER SMC Products Line:tab 5 AIRLINE EQUIPMENT SMC Family:tab 1 ASV FLOW CONTROL QUICK EXHAUST SMC Family Code:tab 11 CB SMC Class Description:tab 8 ASV 1/8 INCH STANDARD (PT) Weight:tab 9 .05751 lb read more
SJT SUCCESS INDUSTRIAL AUTOMATION SDN. BHD. added new photo in OMRON - OMRON SENSOR
Nov 14, 2025 at 03:31 pm —
Omron E2C-X1R5AH Proximity Switch Malaysia

Omron E2C-X1R5AH Proximity Switch Malaysia

Sensing head size M8 Type Heat-resistance model, Cylinder type (with screw) Sensor Head, Shielded Sensing distance 1.5 mm Differential distance 0.04 mm max. Sensing object Ferrous metal (Sensitivity lowers with non-ferrous metals.) Standard sensing object Iron 8 x 8 x 1 mm Response frequency 300 Hz Ambient temperature (Operating) -10 to 200 ℃ Ambient temperature (Storage) -10 to 200 ℃ Ambient humidity (Operating) 35 to 95 % Ambient humidity (Storage) 35 to 95 % Temperature influence ±0.2%/℃ Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude each in X, Y, and Z directions for 2 h Shock resistance Destruction: 500 m/s2 3 times each in X, Y and Z directions Degree of protection IEC: IP60 Connection method Pre-wired models (3 m) Weight Package: Approx. 50 g Material Case: Brass Sensing surface: PEEK Cable: Fluoride resin Clamping nuts: Brass nickel plating Toothed washers: Iron zinc plating Amplifier unit/sensor head of combination E2C-AM4A, E2C-AK4A read more
SJT SUCCESS INDUSTRIAL AUTOMATION SDN. BHD. added new photo in IFM
Nov 14, 2025 at 12:15 pm —
Ifm SM8000 Flow Meter Malaysia

Ifm SM8000 Flow Meter Malaysia

Product characteristics Magnetic-inductive flow meter Connector Process connection: G1 flat seal connection to pipe by means of an adapter Function programmable Totaliser function 2 outputs OUT1 = flow monitoring (binary), flow rate meter (pulse), preset meter (binary) OUT2 = flow monitoring or temperature monitoring (analogue or binary) Input for counter reset Measuring range 0.2...100 l/min read more
SJT SUCCESS INDUSTRIAL AUTOMATION SDN. BHD. added new photo in OMRON - OMRON CJ SERIES
Nov 14, 2025 at 11:57 am —
Omron CJ1W-OC211 Contact Output Unit Malaysia

Omron CJ1W-OC211 Contact Output Unit Malaysia

CJ1W-OC211 Contact Output Unit (16 Points)   Name 16-point Contact Output Unit with Terminal Block Model CJ1W-OC211 Max. Switching Capacity 2 A 250 VAC (cosφ = 1), 2 A 250 VAC (cosφ = 0.4), 2 A 24 VDC (8 A/Unit) Min. Switching Capacity 1 mA 5 VDC Relays NY-24W-K-IE (Fujitsu Takamizawa Components, Ltd.), Cannot be replaced. Service Life of Relay Electrical: 150,000 operations (24 VDC, resistive load)/ 100,000 operations (250 VAC, cosφ = 0.4, inductive load) Mechanical: 20,000,000 operations Service life will vary depending on the connected load. ON Response Time 15 ms max. OFF Response Time 15 ms max. Number of Circuits 16 points/common, 1 circuit Insulation Resistance 20 MΩ between external terminals and the GR terminal (500 VDC) Dielectric Strength 2,000 VAC between the external terminals and the GR terminal for 1 minute at a leakage current of 10 mA max. Internal Current Consumption 110 mA 5 VDC max. 96 mA 24 VDC max. (6 mA × No. of ON points) Weight 170 g max. Circuit Configuration The signal names of the terminals are the device variable names. The device variable names are the names that use ''Jxx'' as the device name. External connection and terminal-device variable diagram The signal names of the terminals are the device variable names. The device variable names are the names that use ''Jxx'' as the device name.     * Terminal numbers A0 to A8 and B0 to B8 are used in the external connection and terminal-device variable diagrams.    They are not printed on the Units.   read more
next page