Rated power supply voltage 100 to 240 VAC 50/60 Hz 100 to 125 VDC Ripple 20% max. (If power supply incorporates a single-phase full-wave rectifier) Allowable voltage variable range 85 to 110% of the power supply voltage Power consumption Relay ON: Approx. 2 VA (at 240 VAC 60 Hz)/Relay OFF: Approx. 1.3 VA (at 240 VAC 60 Hz) Relay ON: Approx. 1.6 W (at 240 VAC 60 Hz)/Relay OFF: Approx. 1.1 W (at 240 VAC 60 Hz) Reset voltage 10% max. of rated supply voltage Number of time ranges 18 Operation mode Flicker OFF start Control output (Type) Time-limit: DPDT Control output (Contact output) Minimum applicable load: 10 mA at 5 VDC (failure level: P Reference value) Operating resetting Time-limit operation/Time-limit reset or Self-reset Ambient temperature range Operating: -10 to 55 ℃ (with no icing) Storage: -25 to 65 ℃ (with no icing) Ambient humidity range Operating: 35 to 85 % Accuracy of operating time ±0.2% FS max. ±0.2% ±10 ms in a range of 1.2 s and 3 s Setting error ±5% FS ±50 ms max. Reset time 0.1 s max. Influence of voltage ±0.2% FS max. ±0.2% ±10 ms in a range of 1.2 s and 3 s Influence of temperature ±1% FS max. (±1% ±10 ms in a range of 1.2 s and 3 s) Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength Between current carrying metal parts and non-current carrying metal parts: 2,000 VAC 50/60 Hz 1 min Between control output terminals and operating circuit: 2,000 VAC 50/60 Hz 1 min Between contacts of different polarity: 2,000 VAC 50/60 Hz 1 min Between non-continuous contacts: 1,000 VAC 50/60 Hz 1 min Impulse withstand voltage Between power terminals: 5 kV Between current carrying terminals and exposed non-current carrying metal parts: 5 kV Noise immunity ±1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) Static immunity Mulfunction: 8 kV, Destruction: 15 kV Vibration resistance Destruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz, 0.5 mm single amplitude each in 3 directions for 10 min Shock resistance Destruction: 980 m/s2, 3 times each in 6 directions Malfunction: 98 m/s2, 3 times each in 6 directions Life expectancy (relay output) Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1800 operations/h) Mechanical: 20 million operations min. (under no load at 1,800 operations/h) Degree of protection IP40 (panel surface) Connecting method 8-pin round socket Weight Approx. 100 g Applicable socket P2CF-08/ P2CF-08-E/ PF085A/ P3G-08/ PL08/ PL08-Q/ PLE08-0
read more