Technical Number of Main Contacts NO: 3 Number of Main Contacts NC: 0 Number of Auxiliary Contacts NO: 0 Number of Auxiliary Contacts NC: 0 Number of Poles: 3P Rated Operational Voltage: Main Circuit 690 V Rated Frequency (f): Main Circuit 50 / 60 Hz Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 160 A Rated Operational Current AC-1 (Ie): (690 V) 40 °C 160 A (690 V) 60 °C 145 A (690 V) 70 °C 130 A Rated Operational Current AC-3 (Ie): (415 V) 55 °C 116 A (440 V) 55 °C 116 A (500 V) 55 °C 110 A (690 V) 55 °C 65 A (380 / 400 V) 55 °C 116 A (220 / 230 / 240 V) 55 °C 116 A Rated Operational Current AC-3e (Ie): (415 V) 60 °C 116 A (440 V) 60 °C 116 A (500 V) 60 °C 110 A (690 V) 60 °C 65 A (380 / 400 V) 60 °C 116 A (220 / 230 / 240 V) 60 °C 116 A Rated Operational Current DC-1 (Ie): (110 V) 2 Poles in Series, 40 °C 145 A (220 V) 3 Poles in Series, 40 °C 145 A Rated Operational Current DC-3 (Ie): (110 V) 2 Poles in Series, 40 °C 145 A (220 V) 3 Poles in Series, 40 °C 145 A Rated Operational Current DC-5 (Ie): (110 V) 2 Poles in Series, 40 °C 145 A (220 V) 3 Poles in Series, 40 °C 145 A Rated Operational Power AC-3 (Pe): (415 V) 55 kW (440 V) 75 kW (500 V) 75 kW (690 V) 55 kW (380 / 400 V) 55 kW (220 / 230 / 240 V) 30 kW Rated Operational Power AC-3e (Pe): (415 V) 55 kW (440 V) 75 kW (500 V) 75 kW (690 V) 55 kW (380 / 400 V) 55 kW (220 / 230 / 240 V) 30 kW Rated Breaking Capacity AC-3: 8 x Ie AC-3 Rated Breaking Capacity AC-3e: 8.5 x Ie AC-3e Rated Making Capacity AC-3: 10 x Ie AC-3 Rated Making Capacity AC-3e: 12 x Ie AC-3e Short-Circuit Protective Devices: gG Type Fuses 250 A Rated Short-time Withstand Current Low Voltage (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 928 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 379 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1160 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 536 A Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2000 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1000 A Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V Rated Impulse Withstand Voltage (Uimp): Main Circuit 8 kV Maximum Electrical Switching Frequency: (AC-1) 300 cycles per hour (AC-2 / AC-4) 150 cycles per hour (AC-3) 300 cycles per hour Mechanical Durability: 5 million Maximum Mechanical Switching Frequency: 300 cycles per hour Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) Rated Control Circuit Voltage (Uc): 50 Hz 100 ... 250 V 60 Hz 100 ... 250 V DC Operation 100 ... 250 V Coil Consumption: Holding at Max. Rated Control Circuit Voltage 50 Hz 6 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 6 V·A Holding at Max. Rated Control Circuit Voltage DC 3 W Pull-in at Max. Rated Control Circuit Voltage 50 Hz 130 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 130 V·A Pull-in at Max. Rated Control Circuit Voltage DC 135 W Power Loss: at Rated Operating Conditions per Pole 6 W Operate Time: Between Coil De-energization and NO Contact Opening 37 ... 47 ms Between Coil Energization and NO Contact Closing 25 ... 55 ms Connecting Capacity Main Circuit: Flexible 2 x 10 ... 70 mm² Rigid Cu-Cable 1 x 10 ... 95 mm² Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² Flexible 2x0.75 ... 2.5 mm² Solid 2 x 1 ... 4 mm² Stranded 1 x 1 .... 4 mm² Connecting Capacity: Flexible 2 x 10 ... 70 mm² Rigid Cu-Cable 2 x 10 ... 95 mm² Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 Tightening Torque: Cable Lug 9 N·m Main Circuit 8 N·m Terminal Type: Double Clamp Product Name: Block Contactor Technical UL/CSA Maximum Operating Voltage UL/CSA: Main Circuit 600 V General Use Rating UL/CSA: (600 V AC) 160 A Horsepower Rating UL/CSA: (200 V AC) Three Phase 30 hp (208 V AC) Three Phase 30 hp (220 ... 240 V AC) Three Phase 40 hp (440 ... 480 V AC) Three Phase 75 hp (550 ... 600 V AC) Three Phase 100 hp Full Load Amps Motor Use: (440 ... 480 V AC) Three Phase 96 A (550 ... 600 V AC) Three Phase 99 A Environmental Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C Close to Contactor for Storage -40 ... 70 °C Maximum Operating Altitude Permissible: Without Derating 3000 m Material Compliance Conflict Minerals Reporting Template (CMRT): CMRT - Conflict Minerals Reporting Template REACH Declaration: REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories RoHS Information: RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 Toxic Substances Control Act - TSCA: Toxic Substances Control Act (TSCA) declaration for Contactors WEEE B2C / B2B: Business To Business WEEE Category: 5. Small Equipment (No External Dimension More Than 50 cm) ABB EcoSolutions ABB EcoSolutions: Yes ABB Site Meeting Group Waste To Landfill Target: Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility End Of Life Disassembling Instructions: End-of-life instruction - AF(S)116(B)-**(RT) to AF(S)205(B)-**(RT) Environmental Product Declaration - EPD: Environmental Product Declaration, AF(S)116-AF(S)146 (SE) Contactors Improved Energy Efficiency for Customers: Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 87.8 % Sustainable Material Content in Product (wt. %): Recycled Metal - 37 %
read more