SJT SUCCESS INDUSTRIAL AUTOMATION SDN. BHD. added new photo in HONEYWELL
Dec 12, 2024 at 10:38 pm —
HONEYWELL RESIDEO D06F-1/2B VALVE MALAYSIA

HONEYWELL RESIDEO D06F-1/2B VALVE MALAYSIA

D06F-1/2B Threaded male connections, brass filter 1/2 in, DN15, Kvs 2.4 SKU: D06F-1/2B The Braukmann D06F pressure reducing valves protect domestic drinking water installations against high pressure and pressure surges in the supply lines according the EN 806-2. Within the range of their specifications, the D06F is suitable for domestic, industrial and commercial installations. read more
SJT SUCCESS INDUSTRIAL AUTOMATION SDN. BHD. added new photo in FOTEK
Dec 12, 2024 at 01:50 am —
SJT SUCCESS INDUSTRIAL AUTOMATION SDN. BHD. added new photo in SMC
Dec 12, 2024 at 01:39 am —
SMC ISE20B-Y-01-W PRESSURE SWITCH

SMC ISE20B-Y-01-W PRESSURE SWITCH

Description  Ordering Guide The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple. tab 7   Documents:tab 3  Series Catalog Click Here for Return Policy SMC Part Description:tab 4 3-Screen High Precision Dig Press Switch   SMC Family:tab 1 PRESSURE SWITCH, ISE1-6 Weight:tab 9 71 lb read more
SJT SUCCESS INDUSTRIAL AUTOMATION SDN. BHD. added new photo in AZBIL
Dec 12, 2024 at 01:28 am —
AZBIL C15MTVOTA0100 TEMPERATURE CONTROLLER MALAYSIA

AZBIL C15MTVOTA0100 TEMPERATURE CONTROLLER MALAYSIA

AZBIL C15MTVOTA0100 TEMPERATURE CONTROLLER MALAYSIA read more
SJT SUCCESS INDUSTRIAL AUTOMATION SDN. BHD. added 2 new photos in SIEMENS - SIMATIC HMI
Dec 12, 2024 at 01:20 am —
SIEMENS 6AV2123-2DB03-0AX0 SIMATIC HMI MALAYSIA
SIEMENS 6AV2123-2GA03-0AX0 SIMATIC HMI MALAYSIA
SJT SUCCESS INDUSTRIAL AUTOMATION SDN. BHD. added new photo in AUTONICS - AUTONICS SENSOR
Dec 12, 2024 at 01:17 am —
Autonics PRD30-25DN Proximity Sensor Malaysia

Autonics PRD30-25DN Proximity Sensor Malaysia

PRD30-25DN Sensing side diameter : M30 Sensing distance : 25mm Installation : Non-shield(non-flush) Standard sensing target : 75×75×1mm(iron) Response frequency : 100Hz Wire type and power DC 3-wire type 12-24VDC  Sensing side diameter M30 Sensing distance 25mm Installation Non-shield(non-flush) Standard sensing target 75×75×1mm(iron) Response frequency 100Hz Current specification Current consumption: Max. 10mA Control output NPN Normally Open Material Brass(nickel plated) Cable Standard/material Standard cable Protection structure IP67 Body length Standard type Environment_Ambient temperature -25 to 70℃, storage: -30 to 80℃ Environment_Ambient humidity 35 to 95% RH, storage: 35 to 95% RH Hysteresis(distance) Max. 10% of sensing distance Residual voltage Max. 1.5V Weight ≈ 143g (≈ 180g) read more
SJT SUCCESS INDUSTRIAL AUTOMATION SDN. BHD. added new photo in MITSUBISHI - MITSUBISHI INVERTER
Dec 12, 2024 at 01:15 am —
MITSUBISHI FR-A840-22K-1 INVERTER MALAYSIA

MITSUBISHI FR-A840-22K-1 INVERTER MALAYSIA

Specifications Primary brand Mitsubishi Electric Main function Variable Speed/Frequency Drive (VSD/VFD) / Inverter Product series / family name FREQROL FR-A800 series Network frequency (output) 0.2-590 Hz Functions Variable Speed/Frequency Drive (VSD/VFD) / Inverter Soft-PWM control High carrier frequency PWM control PM sensorless vector control Maximum and minimum frequency settings Multi-speed operation Acceleration/deceleration pattern Thermal protection DC injection braking Starting frequency JOG operation Output stop (MRS) Stall prevention Regeneration avoidance Increased magnetic excitation deceleration Frequency jump Rotation display Automatic restart after instantaneous power failure Electronic bypass sequence Remote setting Automatic acceleration/deceleration Retry function Carrier frequency selection Fast-response current limit Forward/reverse rotation prevention Operation mode selection Slip compensation Droop control Load torque high-speed frequency control Speed smoothing control Traverse Auto tuning Applied motor selection Gain tuning RS-485 communication PID control PID pre-charge function Easy dancer control Cooling fan operation selection Stop selection (deceleration stop/coasting) Power-failure deceleration stop function Stop-on-contact control PLC function Life diagnosis Maintenance timer Current average monitor Multiple rating Speed control Torque control Position control Pre-excitation Torque limit Test run 24V power supply input for control circuit Safety stop function Anti-sway control DC feeding Design FM term. (PTO output) Forced air cooling Supply voltage (AC) 380Vac-500Vac (400Vac / 415Vac / 480Vac) Type of network 3-phase/3P Rated current 44A (ND Normal Duty) 62A (SLD Super Light duty) 57A (LD Light duty) 38A (HD Heavy Duty) 150% In for 60s / 200% In for 3s overload current rating (inverse-time characteristics; Normal duty; 50°C ambient air temperature) 110% In for 60s / 120% In for 3s overload current rating (inverse-time characteristics; Super light duty; 40°C ambient air temperature) 120% In for 60s / 150% In for 3s overload current rating (inverse-time characteristics; Light duty; 50°C ambient air temperature) 200% In for 60s / 250% In for 3s overload current rating (inverse-time characteristics; Heavy duty; 50°C ambient air temperature) Rated active power (kW) 22kW (ND Normal Duty) 30kW (SLD Super Light Duty) 30kW (LD Light duty) 18.5kW (HD Heavy Duty) Rated power (HP) 30HP Protection functions Overcurrent trip during acceleration Overcurrent trip during constant speed Overcurrent trip during deceleration or stop Regenerative overvoltage trip during acceleration Regenerative overvoltage trip during constant speed Regenerative overvoltage trip during deceleration or stop Inverter overload trip Motor overload trip Heatsink overheat Stall prevention stop Upper limit fault detection Lower limit fault detection Output side earth (ground) fault overcurrent Output short-circuit Output phase loss Option fault Communication Option fault Parameter storage device fault PU disconnection CPU fault Operation panel power Supply short circuit/RS-485 terminals power supply short circuit 24Vdcpower fault Communication fault Analog input fault USB communication fault Safety circuit fault Opposite rotation Internal circuit fault External thermal relay operation (not available in initial status) Loss of synchronism detection PTC thermistor operation Retry count excess Abnormal output current detection Brake sequence fault 4mA input fault Pre-charge fault PID signal fault Deceleration fault Brake transistor alarm detection Instantaneous power failure Undervoltage Input phase loss Inrush current limit circuit fault Overspeed occurrence Communication protocol Modbus RTU Digital inputs 1 x digital input (source/sink) (STF) 1 x digital input (source/sink) (STR) 1 x digital input (source/sink) (STOP) 1 x digital input (source/sink) (RH) 1 x digital input (source/sink) (RM) 1 x digital input (source/sink) (RL) 1 x digital input (source/sink) (JOG) 1 x digital input (source/sink) (RT) 1 x digital input (source/sink) (MRS) 1 x digital input (source/sink) (RES) 1 x digital input (source/sink) (AU) 1 x digital input (source/sink) (CS) 1 x digital input (SS1 safe stop channel 1) 1 x digital input (SS1 safe stop channel 2) Digital outputs 1 x digital output (SPDT (Single Pole Double Throw contact A1/B1/C1) (programmable) 1 x digital output (SPDT Single Pole Double Throw contact A2/B2/C2) (programmable) 1 x digital output (sink/source open collector transistor) (RUN; programmable) 1 x digital output (sink/source open collector transistor) (SU; programmable) 1 x digital output (sink/source open collector transistor) (IPF; programmable) 1 x digital output (sink/source open collector transistor) (OL; programmable) 1 x digital output (sink/source open collector transistor) (FU; programmable) 1 x digital output (PTO Pulse Train Output) (Frequency meter indicator) 1 x digital output (programmable) (SO - Safety Monitor Output) Analog inputs 1 x analog input (0-5Vdc / 0-10Vdc / 0-20mA) 1 x analog input (0-5Vdc / 0-10Vdc) 1 x analog input (0-5Vdc / 0-10Vdc / 4-20mA) Analog outputs 1 x analog output (0-10Vdc) (signal output) Degree of protection IP20 Rated apparent power (S) 34kVA (ND Normal Duty) 47kVA (SLD Super Light Duty) 43kVA (LD Light duty) 29kVA (HD Heavy Duty) Application type Transfer Lift Food Packaging Machine tool Press Printing Winding/unwinding Order code / Manufacturer SKU FR-A840-22K-1 Manufacturer product status Commercialized Equivalent to FRA84022K1 Compliant with standard(s) UL cUL CE KC (South Korea) Radio Waves Act EAC RoHS read more
SJT SUCCESS INDUSTRIAL AUTOMATION SDN. BHD. added 3 new photos in PEPPERL+FUCHS - SAFETY BARRIERS
Dec 12, 2024 at 01:00 am —
PEPPERL+FUCHS KCD2-SR-EX2 MALAYSIA
PEPPERL+FUCHS KCD2-STC-1 MALAYSIA
PEPPERL+FUCHS KCD2-RR2-EX1 MALAYSIA
SJT SUCCESS INDUSTRIAL AUTOMATION SDN. BHD. added 23 new photos in SIEMENS - SIMATIC S7
Dec 12, 2024 at 12:13 am —
SJT SUCCESS INDUSTRIAL AUTOMATION SDN. BHD. added new photo in IFM
Dec 12, 2024 at 12:09 am —
IFM O1D100 O1DLF3KG/IO-LINK SENSOR MALAYSIA

IFM O1D100 O1DLF3KG/IO-LINK SENSOR MALAYSIA

Photoelectric distance sensor O1D100  O1DLF3KG/IO-LINK   Reliable optical distance measurement with high ranges up to 10 m Two switching outputs, one of them programmable as analogue output Scalable measuring range and window function Use in applications with background suppression Excellent price/performance ratio Product characteristics Laser protection class 2 Housing rectangular Electrical data Operating voltage[V] 18...30 DC; (''supply class 2'' to cULus) Current consumption[mA] < 150 Protection class III Reverse polarity protection yes Typ. lifetime[h] 50000 Inputs / outputs Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1 Outputs Total number of outputs 2 Electrical design PNP Number of digital outputs 2 Output function normally open / normally closed; (parameterisable) Max. current load per output[mA] 200 Number of analogue outputs 1 Analogue current output[mA] 4...20; (IEC 61131-2) Max. load[Ω] 250 Analogue voltage output[V] 0...10; (IEC 61131-2) Min. load resistance[Ω] 5000 Short-circuit protection yes Type of short-circuit protection pulsed Overload protection yes Detection zone Max. light spot width[mm] 15 Max. light spot height[mm] 15 Light spot dimensions refer to 10 m Background suppression[m] 0...19 Measuring/setting range Measuring range[m] 0.2...10; (white paper 200 x 200 mm 90% remission) Sampling rate[Hz] 1...50 Interfaces Communication interface IO-Link Transmission type COM2 (38,4 kBaud) IO-Link revision 1.1 SDCI standard IEC 61131-9 Profiles Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis SIO mode yes Required master port type A Process data analogue 2 Process data binary 3 Min. process cycle time[ms] 6 Supported DeviceIDs Type of operation DeviceID default 806 Operating conditions Ambient temperature[°C] -10...60 Protection IP 67 Tests / approvals EMC EN 60947-5-2   Laser protection class 2 Notes on laser protection Caution: laser light Power: <= 4 mW Wave length: 650 nm pulse: 1,3 ns Do not stare into beam.   Avoid exposure to the laser light.   laser class: 2   EN / IEC60825-1:2007   EN / IEC60825-1:2014   Complies with 21 CFR 1040.10 except for conformance with IEC 60825-1 Ed. 3, as described in Laser Notice No. 56, dated May 8, 2019. MTTF[years] 182 Mechanical data Weight[g] 243.5 Housing rectangular Dimensions[mm] 59 x 42 x 52 Materials housing: diecast zinc; front pane: glass; LED window: PC Lens alignment side lens Displays / operating elements Display switching status 2 x LED, yellow operation LED, green distance value, programming alphanumeric display, 4-digit Accessories Accessories (optional) Protective cover, E21133 Remarks Remarks For more information about the measuring range / application please refer to the operating instructions. Pack quantity 1 pcs. Electrical connection Connection Connector: 1 x M12; coding: A Other data Parameter Setting range Factory setting Uni mm, m, inch mm OU1 Hno, Hnc, Fno, Fnc Hno SP1 [mm] 200...9999 1000 nSP1 [mm] 200...9999 800 FSP1 [mm] 200...9999 1200 OU2 Hno, Hnc, Fno, Fnc, I, U I SP2 [mm] 200...9999 2000 nSP2 [mm] 200...9999 1800 FSP2 [mm] 200...9999 2200 ASP [mm] 0...9999 0 AEP [mm] 0...9999 9999 rATE [Hz] 1...50 50 dS1 [s] 0...0.1...5 0 dr1 [s] 0...0.1...5 0 dS2 [s] 0...0.1...5 0 dr2 [s] 0...0.1...5 0 dFo [s] 0...0.1...5 0 dIS d1...3 ; rd1...3; OFF d3 repeatability/accuracy read/write distance (mm) repeatability of the measured values   accuracy     white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission) 200...1000 mm ± 5.0 mm ±7.5 mm ± 15.0 mm ± 18.0 mm 1000...2000 mm ± 5.5 mm ±10.0 mm ± 15.0 mm ± 20.0 mm 2000...4000 mm ± 17.5 mm ±22.5 mm ± 25.0 mm ± 32.0 mm 4000...6000 mm ± 27.5 mm ±40.0 mm ± 35.0 mm ± 50.0 mm 6000...10000 mm ± 60.0 mm   ± 70.0mm   Sampling rate 50 Hz Extraneous light on the object < 40 klx repeatability/accuracy read/write distance (mm) repeatability of the measured values   accuracy     white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission) 200...1000 mm ± 16.5 mm ±16.5 mm ± 26.5 mm ± 26.5 mm 1000...2000 mm ± 16.5 mm ±16.5 mm ± 26.5 mm ± 26.5 mm 2000...4000 mm ± 30.0 mm ±37.0 mm ± 40.0 mm ± 47.0 mm 4000...6000 mm ± 37.0 mm ±57.0 mm ± 47.0 mm ± 67.0 mm 6000...10000 mm ± 75.0 mm — ± 85.0mm — Sampling rate 50 Hz Extraneous light on the object 40...100 klx repeatability/accuracy read/write distance (mm) repeatability of the measured values   accuracy     white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission) 200...1000 mm ± 4.0 mm ±4.5 mm ± 14.0 mm ± 15.0 mm 1000...2000 mm ± 4.5 mm ±6.0 mm ± 14.5 mm ± 16.0 mm 2000...4000 mm ± 13.5 mm ±14.5 mm ± 23.5 mm ± 24.0 mm 4000...6000 mm ± 19.0 mm ±21.0 mm ± 29.0 mm ± 31.0 mm 6000...10000 mm ± 37.0 mm – ± 47.0mm – Sampling rate 1 Hz Extraneous light on the object < 40 klx repeatability/accuracy read/write distance (mm) repeatability of the measured values   accuracy     white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission) 200...1000 mm ± 10.0 mm ± 10.0 mm ± 20.0 mm ± 20.0 mm 1000...2000 mm ± 10.0 mm ± 10.0 mm ± 20.0 mm ± 20.0 mm 2000...4000 mm ± 17.0 mm ± 18.0 mm ± 27.0 mm ± 28.0 mm 4000...6000 mm ± 22.0 mm ± 25.0 mm ± 32.0 mm ± 35.0 mm 6000...10000 mm ± 37.0 mm – ± 47.0mm – Sampling rate 1 Hz Extraneous light on the object < 40...100 klx - - Range on black object (6 % remission) <= 4000 mm - - The values apply at   constant ambient conditions 23 °C / 960 hPa minimum power-on time in minutes 10 read more