Siemens 3RH5921-1FA22 SIRIUS Auxiliary switch Malaysia
|
product brand name |
SIRIUS |
|
product category |
Auxiliary switch |
|
product designation |
auxiliary switch |
|
suitability for use |
Contactor relay and power contactor |
|
General technical data |
|
size of contactor |
S0 |
|
insulation voltage with degree of pollution 3 at AC rated value |
690 V |
|
surge voltage resistance rated value |
6 kV |
|
protection class IP on the front |
IP20 |
|
mechanical service life (operating cycles) typical |
10 000 000 |
|
electrical endurance (operating cycles) at AC-15 at 230 V typical |
200 000 |
|
Substance Prohibitance (day/month/year) |
07/01/2006 |
|
Net Weight |
0.072 kg |
|
number of NC contacts for auxiliary contacts |
|
|
¡ñ instantaneous contact |
2 |
|
number of NO contacts for auxiliary contacts |
|
|
¡ñ instantaneous contact |
2 |
|
number of CO contacts of auxiliary contacts instantaneous contact |
0 |
|
operational current at AC-15 at 690 V rated value |
1 A |
|
operational current of auxiliary contacts at AC-12 |
|
|
¡ñ at 24 V |
10 A |
|
¡ñ at 230 V |
10 A |
|
operational current of auxiliary contacts at AC-14 |
|
|
¡ñ at 125 V |
6 A |
|
¡ñ at 250 V |
6 A |
|
operational current of auxiliary contacts at AC-12 maximum |
10 A |
|
operational current of auxiliary contacts at AC-15 |
|
|
¡ñ at 24 V |
6 A |
|
¡ñ at 230 V |
6 A |
|
¡ñ at 400 V |
3 A |
|
operational current of auxiliary contacts at DC-12 |
|
|
¡ñ at 24 V |
10 A |
|
¡ñ at 110 V |
3 A |
|
¡ñ at 220 V |
1 A |
|
operational current with 2 current paths in series at DC-12 |
|
|
¡ñ at 24 V rated value |
10 A |
|
¡ñ at 60 V rated value |
10 A |
|
¡ñ at 110 V rated value |
4 A |
|
¡ñ at 220 V rated value |
2 A |
|
¡ñ at 440 V rated value |
1.3 A |
|
¡ñ at 600 V rated value |
0.65 A |
|
operational current with 3 current paths in series at DC-12 |
|
|
¡ñ at 24 V rated value |
10 A |
|
¡ñ at 60 V rated value |
10 A |
|
¡ñ at 110 V rated value |
10 A |
|
¡ñ at 220 V rated value |
3.6 A |
|
¡ñ at 440 V rated value |
2.5 A |
|
¡ñ at 600 V rated value |
1.8 A |
|
operational current with 2 current paths in series at DC-13 |
|
|
¡ñ at 24 V rated value |
10 A |
|
¡ñ at 60 V rated value |
3.5 A |
|
¡ñ at 110 V rated value |
1.3 A |
|
¡ñ at 220 V rated value |
0.9 A |
|
¡ñ at 440 V rated value |
0.2 A |
|
¡ñ at 600 V rated value |
0.1 A |
|
operational current with 3 current paths in series at DC-13 |
|
|
¡ñ at 24 V rated value |
10 A |
|
¡ñ at 60 V rated value |
4.7 A |
|
¡ñ at 110 V rated value |
3 A |
|
¡ñ at 220 V rated value |
1.2 A |
|
¡ñ at 440 V rated value |
0.5 A |
|
¡ñ at 600 V rated value |
0.26 A |
|
operational current of auxiliary contacts at DC-13 |
|
|
¡ñ at 24 V |
6 A |
|
¡ñ at 48 V |
2 A |
|
¡ñ at 60 V |
2 A |
|
¡ñ at 110 V |
1 A |
|
¡ñ at 125 V |
0.9 A |
|
¡ñ at 220 V |
0.3 A |
|
¡ñ at 250 V |
0.3 A |
|
contact reliability of auxiliary contacts |
1 faulty switching per 100 million (17 V, 1 mA) |