IFM AC1258 Power Supply Malaysia
Application
|
Design |
housing for DIN rail mounting |
Electrical data
|
Frequency AC[Hz] |
47...64 |
|
Operating voltage tolerance[%] |
10 |
|
Operating voltage[V] |
automatic range selection |
|
Nominal voltage AC[V] |
110 / 230 |
|
Input voltage range AC[V] |
100...120 / 200...240 |
|
Protection class |
I |
|
Overvoltage protection |
yes; (< 36 V) |
|
Max. power-on delay time[ms] |
800 |
|
Output voltage AS-i[V] |
30.5 |
|
Output power (permanent)[W] |
244 |
|
Output power (peak)[W] |
256 |
|
Note on output power (peak)[W] |
|
briefly to load bus capacities after power on |
|
|
Power factor (nominal voltage 120 V AC / 60 Hz) |
0.59 |
|
Power factor (nominal voltage 230 V AC / 50 Hz) |
0.51 |
|
Power reserve[%] |
5 |
|
Number of output circuits |
1 |
|
Output current AS-i[A] |
8 |
|
Max. residual ripple[mV] |
100 |
|
Switch-on peak current (nominal voltage 120 V AC / 60 Hz)[A] |
3 |
|
Switch-on peak current (nominal voltage 230 V AC / 50 Hz)[A] |
3 |
|
Inrush current limitation |
yes |
|
Efficiency (nominal voltage 120 V AC / 60 Hz)[%] |
89.4 |
|
Efficiency (nominal voltage 230 V AC / 50 Hz)[%] |
90.9 |
|
External input protection |
≤ B-10 A / ≤ C-6 A |
|
Derating[W/K] |
6 (60...70 °C) |
|
Mains buffering time (nominal voltage 120 V AC / 60 Hz)[ms] |
44 |
|
Mains buffering time (nominal voltage 230 V AC / 50 Hz)[ms] |
42 |
|
Input current (nominal voltage 120 V AC / 60 Hz)[A] |
3.73 |
|
Input current (nominal voltage 230 V AC / 50 Hz)[A] |
2.23 |
|
Power loss (nominal voltage 120 V AC / 60 Hz)[W] |
28.9 |
|
Power loss (nominal voltage 230 V AC / 50 Hz)[W] |
24.4 |
|
Integrated data decoupling |
yes |
|
Back feeding protection[V] |
35 |
Outputs
|
Short-circuit proof |
yes |
|
Overload protection |
yes |
|
Overload performance |
output current constant |
|
Parallel connection of outputs possible |
no |
|
Series connection of outputs possible |
no |