product brand name |
Class 42 DP Contactors |
|
design of the product |
Non-reversing Definite Purpose Contactor |
|
special product feature |
Snap on auxiliary contacts, enclosed body design |
|
General technical data |
|
weight [lb] |
1.04 lb(av) |
|
Height x Width x Depth [in] |
3.69 × 2.38 × 2.87 in |
|
touch protection against electrical shock |
Not finger-safe |
|
ambient temperature [°F] |
|
|
¡ñ during storage |
158 °F |
|
¡ñ during operation |
158 ... 158 °F |
|
ambient temperature |
|
|
¡ñ during storage |
75 °C |
|
¡ñ during operation |
70 ... 70 °C |
|
country of origin |
China |
|
number of poles for main current circuit |
3 |
|
Horsepower ratings |
|
yielded mechanical performance [hp] for 3-phase AC motor |
|
|
¡ñ at 460/480 V rated value |
10 hp |
|
¡ñ at 575/600 V rated value |
15 hp |
|
Contactor |
|
size of contactor |
30A |
|
number of NO contacts for main contacts |
3 |
|
operating voltage for main current circuit at AC at 60 Hz maximum |
600 V |
|
operational current at AC at 600 V rated value |
120 A |
|
mechanical service life (operating cycles) of the main contacts typical |
250000 |
|
Auxiliary contact |
|
number of NC contacts for auxiliary contacts |
4 |
|
number of NO contacts for auxiliary contacts |
4 |
|
number of NC contacts at contactor for auxiliary contacts |
0 |
|
number of NO contacts at contactor for auxiliary contacts |
0 |
|
number of total auxiliary contacts maximum |
4 |
|
operational current of auxiliary contacts of contactor |
|
|
¡ñ at AC at 600 V |
10 A |
|
contact rating of auxiliary contacts of contactor according to UL |
10A@600VAC (A600), 11A 1/2HP 125-250VAC, 0.6A 125VDC, 0.3A 250VDC |
|
Coil |
|
control supply voltage |
|
|
¡ñ at AC at 50 Hz rated value |
24 V |
|
¡ñ at AC at 60 Hz rated value |
24 V |
|
Enclosure |
|
degree of protection NEMA rating of the enclosure |
Open device (no enclosure) |
|
Mounting/wiring |
|
mounting position |
vertical |
|
fastening method |
Surface mounting and installation |
|
type of electrical connection for supply voltage line-side |
Screw-type terminals |
|
tightening torque [lbf·in] for supply |
40 ... 40 lbf·in |
|
type of connectable conductor cross-sections at line-side for AWG cables single or multi-stranded |
8 AWG |
|
type of electrical connection for load-side outgoing feeder |
Screw-type terminals |
|
type of connectable conductor cross-sections for AWG cables for load-side outgoing feeder single or multi-stranded |
8 AWG |
|
type of electrical connection of magnet coil |
Quick connects, Screw-type terminals |
|
type of electrical connection for auxiliary and control circuit |
Quick Connects, Screw-type terminals |
|
type of electrical connection at contactor for auxiliary contacts |
Screw-type terminals |
|
Certificates/ approvals |
|
certificate of suitability |
cRUus, ARI 780 & 790, UL File E14900 |