Technical

Rated Service Short-Circuit Breaking Capacity (Ics):
(230 V AC) 50 kA
(400 V AC) 50 kA
(440 V AC) 6 kA
(500 V AC) 6 kA
(690 V AC) 2 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(230 V AC) 75 kA
(400 V AC) 75 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(690 V AC) 3 kA
Rated Instantaneous Short-Circuit Current Setting (Ii):
150 A
Setting Range:
6.3 ... 10 A
Rated Operational Power AC-3 (Pe):
(400 V) Three Phase 4 kW
Rated Operational Power AC-3e (Pe):
(400 V) Three Phase 4 kW
Rated Operational Voltage:
Main Circuit 690 V AC
Rated Operational Current (Ie):
10 A
Rated Operational Current AC-3 (Ie):
10 A
Rated Operational Current AC-3e (Ie):
10 A
Rated Frequency (f):
Main Circuit 50 Hz
Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp):
Main Circuit 6 kV
Rated Insulation Voltage (Ui):
690 V
Power Loss:
at Rated Operating Conditions per Pole 0.9 ... 2.4 W
Number of Poles:
3P
Conventional Free-air Thermal Current (Ith):
Main Circuit 10 A
Degree of Protection:
Housing IP20
Main Circuit Terminals IP10
Pollution Degree:
3
Electrical Durability:
100000 cycle
Mechanical Durability:
Nr. Operations 100000 cycle
Terminal Type:
Screw Terminals
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Tightening Torque:
Main Circuit 0.8 ... 1.2 N·m
Wire Stripping Length:
Main Circuit 9 mm
Recommended Screw Driver:
Pozidriv 2
Mounting Position:
1 ... 6
any
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting Distance:
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Contact Position Indication:
ON / OFF
Standards:
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L

Technical UL/CSA

Short-Circuit Current Rating (SCCR):
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 5 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 5 kA
Maximum Operating Voltage UL/CSA:
Main Circuit 600 V AC
Horsepower Rating UL/CSA:
(200 V AC) Three Phase 2 Hp
(208 V AC) Three Phase 2 Hp
(220 ... 240 V AC) Three Phase 3 Hp
(440 ... 480 V AC) Three Phase 5 Hp
(550 ... 600 V AC) Three Phase 7.5 Hp
Full Load Amps Motor Use:
(200 V AC) Three Phase 7.8 A
(208 V AC) Three Phase 7.5 A
(220 ... 240 V AC) Three Phase 9.6 A
(440 ... 480 V AC) Three Phase 7.6 A
(550 ... 600 V AC) Three Phase 9 A
Locked Rotor Amps:
(200 V AC) Three Phase 57.5 A
(208 V AC) Three Phase 55 A
(220 ... 240 V AC) Three Phase 64 A
(440 ... 480 V AC) Three Phase 46 A
(550 ... 600 V AC) Three Phase 50.8 A
General Use Rating UL/CSA:
(600 V AC) 10 A
Connecting Capacity Main Circuit UL/CSA:
Flexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
Tightening Torque UL/CSA:
Main Circuit 10 in·lb