Visit
Official Website

SJT SUCCESS INDUSTRIAL AUTOMATION SDN BHD 956994-D

SJT SUCCESS INDUSTRIAL SUPPLIES 002854041-U

62, Jalan Resak 1/KS7, Bandar Botanik, 41200 Klang, Selangor, Malaysia.
+603-3884 0441
sales@sjtsuccess
.com.my

Pilz PNOZ m0p Safe Controller 773110 Malaysia

Previous 2 / 25 Next


Approval CE  
UKCA  
cULus Listed  
KCC  
KOSHA  
EAC (Eurasian)  
TÜV  
 
Purpose of U1 System supply  
Supply voltage (V) 24  
24  
Type of supply voltage U1 DC  
Purpose of U2 Supply of SC outputs  
Supply voltage U2 24  
24  
Type of supply voltage U2 DC  
Tolerance of U2  
Potential isolation U2 Yes  
Number of digital inputs 20  
20  
Max. no. live inputs U_B <= 26.4 V : 20  
U_B > 26.4 V : 15  
Signal level at input at 0 -3 - +5 VDC  
U input to EN 61131-2 Type 1 24 V DC  
Potential isolation input No  
Number of semicond. outputs 4  
Potential isolation of S/C O Yes  
S/C output short circuit proof Yes  
Number of auxiliary outputs 1  
Galv. isol. n/safe SC O Yes  
Short circ. prot. n/safe S/C O Yes  
Signal level at 1 n/safe S/C O UB - 0.5 VDC at 0.5 A  
Number of test pulse outputs 4  
Number of relay outputs 2  
Utilisation cat. AC/DC1 stand. EN 60947-4-1  
Voltage AC1 safety cont. 240  
Max. current AC1 safety cont. 6  
Voltage DC1 safety cont. 24  
Max. current DC1 safety cont. 6  
Utilisation cat. AC15/DC13sta. EN 60947-5-1  
Voltage AC15 safety cont. 230  
Max. current AC15 safety cont. 3  
Voltage DC13 safety cont. 24  
Pot. isolation relay outputs Yes  
Number of cascading outputs 1  
Galv. isol. casc. aux. S/C O No  
Number of RS 232 interfaces 1  
Ambient temperature standard EN 60068-2-14  
Ambient temperature 0  
60  
Storage temperature standard EN 60068-2-1/-2  
Climatic suitability standard EN 60068-2-30  
EN 60068-2-78  
Humidity rating 93 % r. h. at 40 °C  
Condensation permitted? Not permitted  
Perm. operating height ASL 2000 m  
EMC to standard ... EN 61131-2  
Vibration to standard ... EN 60068-2-6  
Acc. shock to standard1 15g  
Clearance & creepage dist. to EN 61131-2  
Overvoltage category III  
Pollution degree clear.&creep. 2  
Protection type standard EN 60529  
Protection type, mounting  
Protection type, housing IP20  
Terminal protection type  
Potential isolation 1 between SC output and system voltage  
Type of potential isolation 1 Safe separation  
Potential isolation 2 between RL output and system voltage  
Type of potential isolation 2 Safe separation  
Mounting position horizontal on top hat rail  
DIN-rail dimensions 35 x 7.5 EN 50022  
Housing material lower section PPO UL 94 V0  
Housing material front plate ABS UL 94 V0  
Connection terminal Screw terminal  
Spring-loaded terminal  
Flex. cond. c/s AWG info 24 - 16 AWG  
Cond.flex AWG w/o crimp conn. 24 - 12 AWG  
Height dimension 94  
Width dimension 135  
Depth dimension 121  
Net weight 499  
Gross weight 519  

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Messages*