Schneider LC1D09BDC Contactor Malaysia

Previous 11 / 33 Next


Specifications:

Key information
Product range TeSys Deca
Product range TeSys Deca
Product Type: Contactor
Short name of the product LC1D
Contactor application fields It is used in
AC loads with a power factor greater than or equal to 0.95, and is used in non-inductive or slightly inductive loads, and resistance furnaces
Use categories AC-4
AC-1
AC-3
AC-3e
Extreme number 3P
Rated Operating Voltage [UE] Power Circuit: < = 690 V AC 25...400 Hz
Power Circuit: < = 225 V DC
Rated Operating Current [IE] 25 A (when operating temperature <=60 °C) when operating voltage <=<= 440 V AC AC-1 for power circuit
9 A (when operating temperature <=60 °C) when operating voltage <=<= 440 V AC AC-3 For power supply circuit
9 A (when operating temperature <=60 °C) When operating voltage <=<= 440 V AC AC-3e for power loops
Control Loop Voltage [UC] 24 V DC
Additional information
Motor Power (kW) 5.5 kW When operating voltage <=500 V AC 50/60 Hz (AC-3)
2.2 kW When operating voltage <=220/240 V AC 50/60 Hz (AC-3)
4 kW When operating voltage <=380/400 V AC 50/60 Hz (AC-3)
4 kW When operating voltage <=415/440 V AC 50/60 Hz (AC-3)
5.5 kW When operating voltage<=660/690 V AC 50/60 Hz (AC-3)
2.2 kW When operating voltage <=400 V AC 50/60 Hz (AC-4)
5.5 kW When operating voltage <=500 V AC 50/60 Hz (AC-3e).
2.2 kW When operating voltage <=220/240 V AC 50/60 Hz (AC-3e)
4 kW When operating voltage <=380/400 V AC 50/60 Hz (AC-3e)
4 kW When operating voltage <=415/440 V AC 50/60 Hz (AC-3e).
5.5 kW when operating voltage <=660/690 V AC 50/60 Hz (AC-3e)
model LC1D
Loop contact type 3 NO
Protective cover Belt
Agreed Heating Current [Ith] 25 A (when operating temperature <=60 °C) for the power loop
10 A (when operating temperature <=60 °C) for the signal loop
Rated Short-Time Withstand Current [ICW] 105 A for 10 s at <=40 °C for 10 s for the power circuit
210 A for the power circuit at <=40 °C for 10 s for the power circuit
30 A for the <=40 °C for 10 minutes for the power loop
61 A for the <=40 °C for 100 A for the power loop
Lasts 1 s for
the signal loop 120 A for 500 ms for the signal loop
140 A for the signal loop 100 ms for the signal loop
Fuse for use with relays 10 A gG for signal loops in accordance with IEC 60947-5-1
25 A gG when operating voltage <=<= 690 V with type 1,
20 A gG for power loops when operating voltage <=<= 690 V with type 2, for power loops
Average impedance 2.5 mΩ - Ith 25 A 50 Hz for power loops
Rated Insulation Voltage [UI] Power Loop: 690 V in accordance with IEC 60947-4-1
Signal Loop: 690 V in accordance with IEC 60947-1
Overvoltage category III
Contamination level 3
Rated Shock Withstand Voltage [UIMP] 6 kV in accordance with IEC 60947
Safe and reliable level B10d = 1369863 times Contactors with nominal loads in accordance with EN/ISO 13849-1
B10d = 20000000 contactors with mechanical loads in accordance with EN/ISO 13849-1
Mechanical life 30 Mcycles
Electrical life <= 440 V
2 Mcycles 9 A AC-3 Ue at 0.6 Mcycles 25 A AC-1 Ue <= 440 V
2 Mcycles 6.6 A AC-3 Ue at 660/690 V
2 Mcycles 9 A AC-3e Ue <= 440 V
2 Mcycles 6.6 A AC-3e Ue at 660/690 V
Control loop characteristics DC standard
Surge suppression module Built-in bidirectional peak current limiting diode
Control voltage limit 0.1...0.25 Uc (-40… 60 °C): Coil release
0.7...1.25 Uc (-40... 60 °C): Coil start
Surge Power (W) 5.4 W 20 °C)
Gripping Power (W) 5.4 W in... above 20 °C
Rated Operating Power (W) 5.4 W
Action time 63 ± 15 % ms closure and
20 ±20 % ms break
Time constant 28 ms
Maximum operating frequency 3600 times/hour at 60 °C
Wiring capability Power Loop: Bolt Fastening 1 1... 4 mm² Lug OD Ø: 8 mm Cable Type: Flexible Wire Without Terminal Blocks
Power Loop: Bolt Fastening 2 1... 4 mm² Lug OD Ø: 8 mm Cable Type: Flexible Wire Without Terminal Blocks Power
Loop: Bolt Fastening 1 1... 4 mm² Lug OD Ø: 8 mm Cable Type: Flexible Wire with Terminal Blocks
Power Circuit: Bolt Fastening 2 1... 2.5 mm² Lug OD Ø: 8 mm Cable Type: Flexible Wire with Terminal Blocks Power
Circuit: Bolt Fastening 1 1... 4 mm² Lug OD Ø: 8 mm Cable Type: Hardwire Without Terminal Blocks Power
Loop: Bolt Fastening 2 1... 4 mm² lug OD Ø: 8 mm Cable type: Hardwire without terminal blocks
Control loop: Bolt fastening 1 1... 4 mm² Cable Type: Flexible Wire Without Terminal Blocks
Control Loop: Bolt Fastening 2 1... 4 mm² Cable Type: Flexible Cord Without Terminal Blocks
Control Loop: Bolt Fastening 1 1... 4 mm² Cable Type: Flexible Wire with Terminal Blocks Control
Loop: Bolt Fastening 2 1... 2.5 mm² Cable Type: Flexible Wire with Terminal Blocks
Control Loop: Bolt Fastening 1 1... 4 mm² Cable Type: Hardwire Without Terminal Blocks
Control Loop: Bolt Fastening 2 1... 4 mm² Cable Type: Hardwire Without Terminal Blocks Power
Loop: Screw connection
Fastening torque Power circuit: 1.7 N.m Fastening by bolt with screwdriver Ø 6 Flat power
circuit: 1.7 N.m by bolt fastening with screwdriver No 2 Phillips screw
control loop: 1.7 N.m by bolt fastening with screwdriver Ø 6 Flat control
loop: 1.7 N.m by bolt fastening with screwdriver No 2 Phillips
screw Power circuit: 1.7 N.m via cable connector with screwdriver Ø 6 Flat screw: M3.5
Power loop: 1.7 N.m via cable connector with screwdriver No 2 Phillips screw Screw: M3.5
Control loop: 1.7 N.m by bolt fastening with screwdriver pozidriv No 2
Power circuit: 1.7 N.m by bolt fastening with screwdriver pozidriv No 2
Auxiliary contact type Type Mechanical connection 1 NO + 1 NC according to IEC 60947-5-1
Type Mirrored with main contact state 1 NC according to IEC 60947-4-1
Auxiliary contacts available on each contactor 1 NO + 1 NC
Signal loop frequency 25...400 Hz
Minimum Switching Current [Imin] 5 mA for signal loops
Minimum switching voltage 17 V for signal loops
Insulation resistance > 10 MΩ for signal loops
No overlapping time 1.5 ms Loss of power between
NC and NO contacts 1.5 ms Gain power between NC and NO contacts
Installation method: Rail mounting
base plate mounting