Omron G2R-1-SN Relay Malaysia

Previous 6 / 13 Next


Ratings
Operating indicator LED
Degree of protection Closed type (cover)
Terminal structure Plug-in terminal
Coil Coil ratings 24 VDC 25.6 mA
Coil resistance 1113 Ω
Operate voltage (Set voltage) 70 % max.
Release voltage (Reset voltage) 15 % min.
Maximum voltage 110 %
Power consumption Approx. 0.53 W
Contact Contact rated load 250 VAC 10 A (Resistive load)
250 VAC 7.5 A (Inductive load (cosφ = 0.4))
30 VDC 10 A (Resistive load)
30 VDC 5 A (Inductive load (L/R = 7 ms))
Max. contact voltage 440 VAC
125 VDC
Max. contact current AC: 10 A
DC: 10 A
Maximum switching power 2500 VA (Resistive load)
1875 VA (Inductive load (cosφ = 0.4))
300 W (Resistive load)
150 W (Inductive load (L/R = 7 ms))
Contact form SPDT
Contact method Single
Contact material Ag alloy
Performance
Contact resistance 30 mΩ max. (Voltage drop method with 5 VDC 1 A)
Operating time 15 ms max. (With rated operating power applied, not including contact bounce)
Reset time 5 ms max. (With rated operating power applied, not including contact bounce)
Maximum operating frequency Mechanical: 18000 time/hour
Rated load: 1800 time/hour
Insulation resistance Between coil and contacts: 1000 MΩ min. (at 500 VDC)
Between contacts of same polarity: 1000 MΩ min. (at 500 VDC)
Dielectric strength Between coil and contacts: 5000 VAC 50/60 Hz 1 min
Between contacts of same polarity: 1000 VAC 50/60 Hz 1 min
Vibration resistance (destruction) 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Vibration resistance (Malfunction) 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Shock resistance (destruction) 1000 m/s2
Shock resistance (Malfunction) Energized: 200 m/s2
No energized: 100 m/s2
Endurance (Mechanical) 20 million operations min. (switching frequency 18,000 operations/h)
Endurance (Electrical) 100,000 operations min. (Rated load, switching frequency 1,800 operations/h)
Failure rate 100 mA at 5 VDC (failure level: Preference value, Switching frequency: 120 operations per minute)
Ambient temperature (Operating) -40 to 70 ¡æ (with no freezing or condensation)
Ambient humidity (Operating) 5 to 85 %
Weight Approx. 20 g
Mounting method Socket
Applicable socket P2RFZ-05/ P2RFZ-05-E/ P2RF-05-PU/ P2R-057P/ P2R-05A/ P2R-05P