- SIEMENS
- MITSUBISHI
- ABB
- ALLEN-BRADLEY
- AMPROBE
- AUTONICS
- AZBIL
- BALLUFF
- BAUMER
- BECKHOFF
- BURKERT
- CKD
- DATALOGIC
- DELTA
- DKM
- EATON
- EATON BUSSMANN
- EUCHNER
- FESTO
- FLUKE
- FOTEK
- FUJI
- HENGSTLER
- HONEYWELL
- IDEC
- IFM
- KEYENCE
- KINCO
- KOGANEI
- KOYO
- LEADSHINE
- LENZE
- LEUZE
- LS
- MEANWELL
- MOUJEN
- NIDEC
- NORGREN
- OMRON
- ORIENTAL MOTOR
- PANASONIC
- PARKER
- PEPPERL+FUCHS
- PILZ
- PIZZATO
- REXROTH
- RIKO
- SANYO DENKI
- SCHMERSAL
- SCHNEIDER
- SCHREIBER MESSTECHNIK
- SMC
- TECO
- TOSHIBA
- YASKAWA
- Others
SJT SUCCESS INDUSTRIAL AUTOMATION SDN BHD 956994-D
SJT SUCCESS INDUSTRIAL SUPPLIES 002854041-U
62, Jalan Resak 1/KS7, Bandar Botanik, 41200 Klang, Selangor, Malaysia.
+603-3884 0441
sales@sjtsuccess.com.my
Fluke 6200-2 Portable Appliance Testers Malaysia
| Previous | 1 / 12 | Next |
Specifications: Fluke 6200-2 Portable Appliance Testers
| Specifications | ||
| Test specifications | The accuracy specification for the display range is defined as ±(%reading + digit counts) at 23 °C ±5 °C, ≤75% RH. | |
| Between 0 °C and 18 °C and between 28 °C and 40 °C, accuracy specifications may degrade by 0.1 x (accuracy specification) per °C. | ||
| The measurement range meets the service operating errors specified in EN61557-1: 1997, EN61557-2: 1997, EN61557-4: 1997, EN61557-6: 1997, DIN VDE0404-2. | ||
| Power-on test | The test indicates reversed L-N, missing PE, and measures the mains voltage and frequency. | |
| Display range | 90 V to 264 V | |
| Accuracy at 50 Hz | ±(2% + 3 counts) | |
| Resolution | 1 V | |
| Input impedance | > 1 MΩ // 2.2 nF | |
| Maximum input mains voltage | 264 V | |
| Earth bond test (R pe) | Display Range | 0 to 19.99 Ω |
| Accuracy (after bond test zeroing) | ±(2.5% + 4 counts) | |
| Resolution | 0.01 Ω | |
| Test current |
200 mA AC -0% +40% into 1.99 Ω 25 A AC ±20% into 25 mΩ at 230 V |
|
| Open circuit voltage | > 4 V AC, < 24 V AC | |
| Bond test zeroing | can subtract up to 1.99 Ω | |
| Insulation test (R iso) | Display range | 0 to 299 MΩ |
| Accuracy | ±(5% + 2 counts) from 0.1 to 300 MΩ | |
| Resolution |
0.01 MΩ (0 to 19.99 MΩ) 0.1 MΩ (20 to 199.9 MΩ) 1 MΩ (200 to 299 MΩ) |
|
| Test voltage | 500 V DC -0% + 10% at 500 kΩ load | |
| Test current | > 1 mA at 500 kΩ load, < 15 mA at 0 Ω | |
| Auto discharge time | < 0.5 s for 1 μF | |
| Max. capacitive load | Operational up to 1 μF | |
| Touch current test | Display range | 0 to 1.99 mA AC |
| Accuracy | ±(4% + 2 counts) | |
| Resolution | 0.01 mA | |
| Internal resistance (via probe) | 2 kΩ | |
| Measuring method | Probe* | |
| Substitute leakage current test | Display range | 0 to 19.99 mA AC |
| Accuracy | ±(2.5% + 3 counts) | |
| Resolution | 0.01 mA | |
| Test Voltage | 100 V AC ±20% | |
| Load/leakage test: load current | Display range | 0 A to 13 A |
| Accuracy | ±(4% + 2 counts) | |
| Resolution | 0.1 A* | |
| Load/leakage test: load power | Display range 230 V Mains | 0.0 VA to 3.2 kVA |
| Accuracy | ±(5% + 3 counts) | |
| Resolution | 1 VA (0 to 999 VA), 0.1 kVA (>1.0 kVA)* | |
| Load/leakage test: leakage current | Display range | 0 to 19.99 mA |
| Accuracy | ±(4% + 4 counts) | |
| Resolution | 0.01 mA* | |
| PELV test | Accuracy at 50 Hz | ±(2% + 3 counts) |
| Overload protection | 300 V rms | |
| Warning threshold | 25 V rms | |
| *The appliance under test is energized at mains potential. | ||
| Environmental specifications | |
| Operating temperature | 0 to 40 °C |
| Relative humidity | Non condensing <10 °C |
| 95% from 10 to 30 °C | |
| 75% from 30 to 40 °C | |
| Safety specifications | ||
| Safety rating | Complies with EN61010-1 3rd edition | |
| CAT II, 300 V, pol 2 | ||
| Mechanical and general specifications | ||
| Size (L x W x H) | 200 x 275 x 114 mm | |
| Weight | 3.13 kg | |
| Power supply | 230 V +10% -15%, 50 Hz ±2 | |
| Power consumption (tester) |
13 W typical (idle) 60 W max. during 25A Bond test |
|
| Storage | Temperature | -10 to 60 °C |
| Corrosion | 70 °C @ 95% RH for 5 days max. | |
| Operating altitude | 0 up to 2000 m | |
| Sealing | IP-40 (enclosure), IP-20 (connectors) | |
| EMC | Complies with EN61326-1, portable | |
| EMI Immunity | 3 V/m | |