Visit
Official Website

IFM SA5000 FLOW SENSOR

Previous 1 / 2 Next


Flow sensor

SA5000

SAD10XDBFRKG/US-100

  • Measurement of flow and temperature at the same time
  • Optimised for water, oils and air
  • Red/green display for clear identification of the acceptable range
  • With switching output, analogue signal and IO-Link
  • The process connection can be rotated for optimum alignment
  • Convenient operation via buttons or parameter setting via IO-Link

Product characteristics

Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Process connection threaded connection M18 x 1,5 internal thread

Application

Special feature Gold-plated contacts
Media water; glycol solutions; air; oils
Note on media
low-viscosity oils with viscosity: ≤ 40 mm²/s (40 °C)
high-viscosity oils with viscosity: > 40 mm²/s (40 °C)
Medium temperature[°C] -20...90
Pressure rating[bar] 100
Pressure rating[MPa] 10
MAWP (for applications according to CRN)[bar] 100

Electrical data

Operating voltage[V] 18...30 DC
Current consumption[mA] < 100
Protection class III
Reverse polarity protection yes
Power-on delay time[s] 10
Measuring principle calorimetric

Inputs / outputs

Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1

Outputs

Total number of outputs 2
Output signal switching signal; analogue signal; frequency signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] 2.5
Permanent current rating of switching output DC[mA] 250
Number of analogue outputs 1
Analogue current output[mA] 4...20; (scalable)
Max. load[Ω] 350
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Frequency of the output[Hz] 0...1000

Measuring/setting range

Probe length L[mm] 45
Operating mode relative; absolutely liquid; absolutely gaseous; (absolute: reference measurement recommended; Factory setting: relative)
Temperature monitoring
Measuring range[°C] -20...90
Resolution[°C] 0.2
Liquid media - absolute operating mode
Setting range[m/s] 0.04...3
Greatest sensitivity[m/s] 0.04...3
Liquid media - relative operating mode
Setting range[m/s] 0.04...6
Greatest sensitivity[m/s] 0.04...3
Gases - operating mode ''absolute''
Setting range[m/s] 0...100
Greatest sensitivity[m/s] 30...100
Gases - operating mode ''relative''
Setting range[m/s] 0...200
Greatest sensitivity[m/s] 30...100

Accuracy / deviations

Temperature drift[cm/s x 1/K] 0,003 m/s x 1/K (< 20 °C; > 70 °C)
Temperature gradient[K/min] 100
Absolute operating mode
Repeatability 0,05 m/s; (water; flow velocity: 0,05...3 m/s)
Relative operating mode
Accuracy ± (7 % MW + 2 % MEW); (for relative mode in the range of maximum sensitivity under the following conditions:; water: 20...70 °C; inlet length: 1.5 m; DN25 (DIN 2448); mounting position according to instructions; Accuracy can differ for other media and mounting positions.)
Repeatability 0,05 m/s; (water; flow velocity: 0,05...3 m/s)
Temperature monitoring
Temperature drift ± 0,005 K/°C
Accuracy[K] ± 0,3 / ± 1; (water; flow velocity: 0,3...3 m/s / air; flow velocity: > 10 m/s)

Response times

Response time[s] 0.5; (T09; water; glycol: 0,8 s; air: 7 s; oil: 1,8 s; each T09)
Temperature monitoring
Dynamic response T05 / T09[s] 1,5 (T09); (water; flow velocity: 0,3...3 m/s)

Software / programming

Parameter setting options hysteresis / window; normally open / normally closed; switching logic; current/frequency output; medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value colour

Interfaces

Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode yes
Required master port type A
Process data analogue 2
Process data binary 2
Min. process cycle time[ms] 3
Supported DeviceIDs
Type of operation DeviceID
Factory setting / ModE = (REL) 533
ModE = (GAS) 547
ModE = (LIQU) 540

Operating conditions

Ambient temperature[°C] -40...80
Storage temperature[°C] -40...100
Protection IP 65; IP 67

Tests / approvals

EMC
DIN EN 60947-5-9  
Shock resistance
DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 20 g (10...2000 Hz)
MTTF[years] 132
UL approval
UL Approval no. I003
File number UL E174189

Please leave your enquiry here, we will reply as soon as possible.