- SIEMENS
- MITSUBISHI
- ABB
- ALLEN-BRADLEY
- AMPROBE
- AUTONICS
- AZBIL
- BALLUFF
- BAUMER
- BECKHOFF
- BURKERT
- CKD
- DATALOGIC
- DELTA
- DKM
- EATON
- EATON BUSSMANN
- EUCHNER
- FESTO
- FLUKE
- FOTEK
- FUJI
- HENGSTLER
- HONEYWELL
- IDEC
- IFM
- KEYENCE
- KINCO
- KOGANEI
- KOYO
- LEADSHINE
- LENZE
- LEUZE
- LS
- MEANWELL
- MOUJEN
- NIDEC
- NORGREN
- OMRON
- ORIENTAL MOTOR
- PANASONIC
- PARKER
- PEPPERL+FUCHS
- PILZ
- PIZZATO
- REXROTH
- RIKO
- SANYO DENKI
- SCHMERSAL
- SCHNEIDER
- SCHREIBER MESSTECHNIK
- SMC
- TECO
- TOSHIBA
- YASKAWA
- Others
SJT SUCCESS INDUSTRIAL AUTOMATION SDN BHD 956994-D
SJT SUCCESS INDUSTRIAL SUPPLIES 002854041-U
62, Jalan Resak 1/KS7, Bandar Botanik, 41200 Klang, Selangor, Malaysia.
+603-3884 0441
sales@sjtsuccess.com.my
IFM AC1258 Power Supply Malaysia
| Previous | 2 / 11 | Next |
Application
| Design | housing for DIN rail mounting |
Electrical data
| Frequency AC[Hz] | 47...64 | |
| Operating voltage tolerance[%] | 10 | |
| Operating voltage[V] | automatic range selection | |
| Nominal voltage AC[V] | 110 / 230 | |
| Input voltage range AC[V] | 100...120 / 200...240 | |
| Protection class | I | |
| Overvoltage protection | yes; (< 36 V) | |
| Max. power-on delay time[ms] | 800 | |
| Output voltage AS-i[V] | 30.5 | |
| Output power (permanent)[W] | 244 | |
| Output power (peak)[W] | 256 | |
| Note on output power (peak)[W] |
|
|
| Power factor (nominal voltage 120 V AC / 60 Hz) | 0.59 | |
| Power factor (nominal voltage 230 V AC / 50 Hz) | 0.51 | |
| Power reserve[%] | 5 | |
| Number of output circuits | 1 | |
| Output current AS-i[A] | 8 | |
| Max. residual ripple[mV] | 100 | |
| Switch-on peak current (nominal voltage 120 V AC / 60 Hz)[A] | 3 | |
| Switch-on peak current (nominal voltage 230 V AC / 50 Hz)[A] | 3 | |
| Inrush current limitation | yes | |
| Efficiency (nominal voltage 120 V AC / 60 Hz)[%] | 89.4 | |
| Efficiency (nominal voltage 230 V AC / 50 Hz)[%] | 90.9 | |
| External input protection | ≤ B-10 A / ≤ C-6 A | |
| Derating[W/K] | 6 (60...70 °C) | |
| Mains buffering time (nominal voltage 120 V AC / 60 Hz)[ms] | 44 | |
| Mains buffering time (nominal voltage 230 V AC / 50 Hz)[ms] | 42 | |
| Input current (nominal voltage 120 V AC / 60 Hz)[A] | 3.73 | |
| Input current (nominal voltage 230 V AC / 50 Hz)[A] | 2.23 | |
| Power loss (nominal voltage 120 V AC / 60 Hz)[W] | 28.9 | |
| Power loss (nominal voltage 230 V AC / 50 Hz)[W] | 24.4 | |
| Integrated data decoupling | yes | |
| Back feeding protection[V] | 35 |
Outputs
| Short-circuit proof | yes |
| Overload protection | yes |
| Overload performance | output current constant |
| Parallel connection of outputs possible | no |
| Series connection of outputs possible | no |